Trade claims weighed in the open: what shops attested, what outcomes proved, what documents anchor. Points are the weighing, not a vote — shop evidence on one lane, documents on the other, and the two are never averaged into a single score when a claim is contested. Refuted claims keep their points and sit capped below the evidence that refuted them.
Nothing here is Judge Certified. No electrical bench exists yet; bench recruiting starts now the storehouse is open. Safety-flagged entries describe a rule or a practice — they are not instructions, and the two entries held for bench review are published as register lines only.
ED-1-Limb-B · Backed by shops + documents · 10 points of shop evidence · checked against documents (+5)Documentary-high
ED-1 · Limb B — The manufacturer's test button is the GFCI test; plug-in testers are not listed for testing GFCIs
Shop 10 · Doc 5 · Total 15. Band: Both lanes high.
Provenance: convergence-pass-7-increment.md §2 (Both lanes high); anchor: ◆ Leviton SmartlockPro instructions, `manufacturer_document`
ED-1-Limb-A · Backed by shops + documents · 7 points of shop evidence · checked against documents (+5)Points-high, voices-shortDocumentary-high
ED-1 · Limb A — A plug-in tester cannot trip a GFCI where no EGC exists
Shop 7 · Doc 5 · Total 12. Band: Both lanes high.
Provenance: convergence-pass-7-increment.md §2 (Both lanes high); anchor: Sperry VD7504GFI Operating Instructions, `manufacturer_document`, hunt 25
ED-20-M2 · Backed by shops + documents · 2 points of shop evidence · checked against documents (+10)Documentary-high
ED-20 · M2 — A factory-bonded meter/main carries "Suitable only for use as service equipment" by requirement of its listing — and a manufacturer's own meter/main instructions print exactly that marking over exactly that construction
Shop 2 · Doc 10 · Total 12. Band: Documentary-high.
Provenance: convergence-pass-7-increment.md §2 (Documentary-high)
ED-5-M6 · Backed by shops + documents · 6 points of shop evidence · checked against documents (+5)Documentary-high
ED-5 · M6 — UL 3741 listed assemblies are the MLPE-free rapid-shutdown path, at full assembly discipline
Shop 6 · Doc 5 · Total 11. Band: Documentary-high.
Provenance: convergence-pass-7-increment.md §2 (Documentary-high); anchor: ◆ EcoFasten instructions, `manufacturer_document`
ED-16-M4 · Backed by shops + documents · 5 points of shop evidence · checked against documents (+5)Documentary-high
ED-16 · M4 — The 30 A SSR is a power controller, not a control device (its own UL listing says so)
Shop 5 · Doc 5 · Total 10. Band: Documentary-high.
Provenance: convergence-pass-7-increment.md §2 (Documentary-high); anchor: ◆ UL NMFT2 directory entry, `listing_certification_document`
✕ Shown wrong
REFUTED — IDEC's no-SCCR position as applied to its own 30 A SSR (thread 2559098 post #11, the manufacturer's support/product management, quoted verbatim). Vendor lane +0 (a vendor on its own wares). Rebutted from the manufacturer's own UL listing (NMFT2.E194577, Motor Controllers), which classifies the device as a power controller; the landed listing anchor at ED-16 M4 converted the cap to a formal refutation on classification grounds. Two limits ride with it: the firsthand capture of the listing entry is still owed, and the thread's 5 kA SCCR figure does not appear in the public listing excerpt and is not listing-established. The vendor's general rule — true control-circuit devices need no SCCR — is NOT refuted; it is correct for its scope and is preserved inside ED-16 M4's statement.
ED-17-M12 · Backed by shops + documents · 5 points of shop evidence · checked against documents (+5)Points-high, voices-shortSingle voiceDocumentary-high
ED-17 · M12 — Grandfathering: what was legal then is legal now; backward reach needs a danger-level defect — and two appeals were won on it
Shop 5 · Doc 5 · Total 10. Band: Documentary-high.
Provenance: convergence-pass-7-increment.md §2 (Documentary-high); anchor: WAC 296-46B-010(14
ED-4-M8 · Backed by shops + documents · 4 points of shop evidence · checked against documents (+5)Documentary-high
ED-4 · M8 — Tesla's Gen 3 manual: integrated CCID20, and "do not install a GFCI circuit breaker."
Shop 4 · Doc 5 · Total 9. Band: Documentary-high.
Provenance: convergence-pass-7-increment.md §2 (Documentary-high); anchor: Tesla Gen 3 Wall Connector Installation Manual, `manufacturer_document`, product scope
ED-17-M10 · Backed by shops + documents · 4 points of shop evidence · checked against documents (+5)Documentary-high
ED-17 · M10 — The correct channel for pre-existing violations is written issuance to the property owner, not a failure on the new-work permit
Shop 4 · Doc 5 · Total 9. Band: Documentary-high.
Provenance: convergence-pass-7-increment.md §2 (Documentary-high); anchor: MA GL c. 143, § 3L + c. 166, § 32, `adopted_document` — one class, counted once, hunt 21
ED-19-M3 · Backed by shops + documents · 3 points of shop evidence · checked against documents (+5)Documentary-high
ED-19 · M3 — The 2026 NEC deleted 230.85 and relocated its requirement into 230.70(A)(1)
Shop 3 · Doc 5 · Total 8. Band: Documentary-high.
Provenance: convergence-pass-7-increment.md §2 (Documentary-high); anchor: Oregon BCD 2026 OESC Table of Amendments, `adopted_document`
ED-14-M2a · Backed by shops + documents · 2 points of shop evidence · checked against documents (+5)Documentary-high
ED-14 · M2a — Massachusetts requires the copper grid for inground pools: the (B)(2)(b) ring alternate is above-ground-only
Shop 2 · Doc 5 · Total 7. Band: Documentary-high.
Provenance: convergence-pass-7-increment.md §2 (Documentary-high); anchor: 527 CMR 12.00, 2023 MEC, `adopted_document`
ED-15-M1 · Backed by shops + documents · 2 points of shop evidence · checked against documents (+5)Documentary-high
ED-15 · M1 — The Tennessee marina ground-fault limb
Shop 2 · Doc 5 · Total 7. Band: Documentary-high.
Provenance: convergence-pass-7-increment.md §2 (Documentary-high); anchor: ◆ Tenn. Comp. R. & Regs. 0780-02-01-.22(3
ED-4-M5 · Backed by shops + documents · 2 points of shop evidence · checked against documents (+5)Single voiceDocumentary-high
ED-4 · M5 — 210.8(F)'s reach, and South Dakota's exception to it
Shop 2 · Doc 5 · Total 7. Band: Documentary-high.
Provenance: convergence-pass-7-increment.md §2 (Documentary-high); anchor: ◆ SD adopted-code exceptions document, `adopted_document`, both cycles
ED-18-M3 · Backed by shops + documents · 2 points of shop evidence · checked against documents (+5)Documentary-high
ED-18 · M3 — North Carolina's 50-ft AFCI extension relief is real — at 210.12(D), not (E)
Shop 2 · Doc 5 · Total 7. Band: Documentary-high.
Provenance: convergence-pass-7-increment.md §2 (Documentary-high); anchor: NC OSFM 2017 + 2020 amendment packages, `adopted_document`
ED-4-M7 · Backed by shops + documents · 1 points of shop evidence · checked against documents (+5)Documentary-high
ED-4 · M7 — ChargePoint instructs a non-GFCI breaker for the Home Flex, and hard-wiring where GFCI is required
Shop 1 · Doc 5 · Total 6. Band: Documentary-high.
Provenance: convergence-pass-7-increment.md §2 (Documentary-high); anchor: ChargePoint Electrician's Pre-Installation Tips, `manufacturer_document`, product scope
ED-15-M3 · Widely backed by shops · 8 points of shop evidence
ED-15 · M3 — Marina feeder compliance runs through a ground-fault monitor + shunt-trip breaker; no 100 mA snap-in breaker exists at that size
Shop 8 · Doc 0 · Total 8. Band: Shop lane ≥6.
Provenance: convergence-pass-7-increment.md §2 (Shop lane ≥6)
ED-20-M1 · Widely backed by shops · 8 points of shop evidence
ED-20 · M1 — The 230.85(3) marking keeps the inside panel the service disconnect: OCP allowed outside, 3-wire service-conductor feed, bonding and GECs stay inside
Shop 8 · Doc 0 · Total 8. Band: Shop lane ≥6.
Provenance: convergence-pass-7-increment.md §2 (Shop lane ≥6)
ED-4-M9 · Widely backed by shops · 7 points of shop evidence
ED-4 · M9 — The 2023 NEC's 625.44 permits 60 A receptacles for EVSE (125/250 V, four-wire only)
Shop 7 · Doc 0 · Total 7. Band: Shop lane ≥6.
Provenance: convergence-pass-7-increment.md §2 (Shop lane ≥6)
ED-11-M2 · Widely backed by shops · 7 points of shop evidencePoints-high, voices-short
ED-11 · M2 — An SLC may not share a raceway with a 120 V circuit — with the reported troubles to prove the point
Shop 7 · Doc 0 · Total 7. Band: Shop lane ≥6.
Provenance: convergence-pass-7-increment.md §2 (Shop lane ≥6)
ED-16-M2-Limb-A · Widely backed by shops · 7 points of shop evidenceContested
ED-16 · M2 Limb A — Field fuses do not cure a low SCCR label; impedance or rebuild are the remedies
Shop 7 · Doc 0 · Total 7. Band: Shop lane ≥6.
Provenance: convergence-pass-7-increment.md §2 (Shop lane ≥6)
ED-2-Limb-A · Widely backed by shops · 6 points of shop evidence
ED-2 · Limb A — The lost-neutral signature and load-test pattern
Shop 6 · Doc 0 · Total 6. Band: Shop lane ≥6.
Provenance: convergence-pass-7-increment.md §2 (Shop lane ≥6)
ED-3-M11 · Widely backed by shops · 6 points of shop evidence
ED-3 · M11 — 2023 NEC 220.50(B) routes hermetic A/C loads through Article 440 Part IV; the 25% lands once per group
Shop 6 · Doc 0 · Total 6. Band: Shop lane ≥6.
Provenance: convergence-pass-7-increment.md §2 (Shop lane ≥6)
ED-6-M6 · Widely backed by shops · 6 points of shop evidenceContested
ED-6 · M6 — 408.41's "terminate" is the final point; spliced neutrals still terminate on the bar
Shop 6 · Doc 0 · Total 6. Band: Shop lane ≥6.
Provenance: convergence-pass-7-increment.md §2 (Shop lane ≥6)
ED-7-M1 · Widely backed by shops · 6 points of shop evidence
ED-7 · M1 — Number the directory by space, never by breaker sequence
Shop 6 · Doc 0 · Total 6. Band: Shop lane ≥6.
Provenance: convergence-pass-7-increment.md §2 (Shop lane ≥6)
ED-8-M2 · Widely backed by shops · 6 points of shop evidence
ED-8 · M2 — Separate transfer switches per load class exist to isolate failures from the emergency supply
Shop 6 · Doc 0 · Total 6. Band: Shop lane ≥6.
Provenance: convergence-pass-7-increment.md §2 (Shop lane ≥6)
ED-17-M1 · Widely backed by shops · 6 points of shop evidence
ED-17 · M1 — An AHJ is not bound by a prior erroneous approval; the fix-it duty runs to the owner, the paperwork lands on your permit
Shop 6 · Doc 0 · Total 6. Band: Shop lane ≥6.
Provenance: convergence-pass-7-increment.md §2 (Shop lane ≥6)
ED-17-M5 · Widely backed by shops · 6 points of shop evidence
ED-17 · M5 — The paper-shield playbook: timestamped photos, a certified letter scoping your work in the job folder, scope language on the final certificate
Shop 6 · Doc 0 · Total 6. Band: Shop lane ≥6.
Provenance: convergence-pass-7-increment.md §2 (Shop lane ≥6)
ED-19-M1 · Widely backed by shops · 6 points of shop evidenceContested
ED-19 · M1 — A locked gate does not defeat "readily accessible" as the definition is written
Shop 6 · Doc 0 · Total 6. Band: Shop lane ≥6.
Provenance: convergence-pass-7-increment.md §2 (Shop lane ≥6)
ED-6-M7 · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-6 · M7 — 408.41 strict-text dissent, CONTESTED
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-9-M4 · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-9 · M4 — wire nuts permitted in Class I Div 2, 2005-bound
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
Retired
RETIRED to permanent relay status — the Crouse-Hinds wire-nut position (ED-9 M6). A manufacturer's statement about its own field, quoted second-hand by a poster: vendor lane +0, never anchored. The document hunt read Eaton's own Code Digest substantially in search of the position; “wire nut” appears nowhere in it. No further hunts run unless Crouse-Hinds publishes the position. Filed as the position ED-9 M4's practitioners independently reach.
ED-16-M1 · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-16 · M1 — assembler determines SCCR; AIC ≠ SCCR
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-16-M3b · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-16 · M3b — the rejected 5 kA drive panel
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-14-M2b · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-14 · M2b — inspector accepted bonded steel mesh, commercial pool
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-8-M6 · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-8 · M6 — unverifiable generator size drew the correction
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-3-M3 · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-3 · M3 — the method-changed maxim
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-3-M4 · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-3 · M4 — re-derive the spreadsheet
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-2-Limb-C · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-2 · Limb C — the dryer bonding-jumper mechanism case
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-6-M1 · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-6 · M1 — the GEC terminates where the MBJ is
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-12-M1 · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-12 · M1 — CL2/CL3 are not "nonmetallic-sheathed cables," 2023
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-21-M1 · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-21 · M1 — megger method against the temperature-corrected floor
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-21-M2 · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-21 · M2 — identical readings are a configuration artifact first
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-21-M5 · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-21 · M5 — the Danfoss ribbon-cable case
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-19-M2 · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-19 · M2 — the purpose limb, CONTESTED; ◆3/◆4 shelf-life notes as M1's, ◆6 completable at 8 of 8 as M1's
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-17-M7-Limb-A · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-17 · M7 Limb A — the reporting-ethics dissent, CONTESTED limb
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line); limb of member M7 — the court's 141-member count treats this member's limbs as one member (see READINESS.md)
ED-17-M14 · Backed by a few shops · 5 points of shop evidenceContestedSafety-flaggedSingle voice
ED-17 · M14 — the touched-panel outcome: 277 V on the EGC, contractor on the hook — single voice, review-side; the field case behind M2's exception; safety-flagged; Increment 5 §1
Shop 5 · Doc 0 · Total 5. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-1-race · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-1 · race member — The AFCI race: a plug-in tester's hot-to-ground fault presents an arc signature the upstream AFCI acts on before the GFCI's differential detection completes (Pass 1 member, thread 2586144 WI-1 second half)
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-1-workarounds · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-1 · workarounds member — Workarounds when an inspector insists on plug-in testing: temporary plain breaker for the test, or dual-function breaker + standard duplex (SAFETY-HELD for bench review)
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-2-Limb-D · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-2 · Limb D — Corroborating checks: current on the CATV/phone bonds betrays a compromised service neutral; do not accept the utility's unloaded no-find — press for a loaded meter test (the "beast of burden")
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-3-M10 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-3 · M10 — The MCA back-out: a nameplate MCA embeds 125% of the unit's largest motor; subtract that 25% per unit, add 125% of the group's largest motor once — never stack the factor unit over unit
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-4-M1 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-4 · M1 — mechanism, not intention
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-5-M1 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-5 · M1 — Rapid-shutdown initiation need not act as one: up to six switches, grouped and labeled as rapid-shutdown switches, by analogy to service-disconnect grouping
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-5-M5 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-5 · M5 — proximity ≠ compliance
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-7-M3 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-7 · M3 — spare-breaker directory duty
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-8-M1 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-8 · M1 — three load classes, one switch per class
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-8-M4 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-8 · M4 — 702.5 enforcement gap
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-10-M1 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-10 · M1 — three-question framework
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-12-M2 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-12 · M2 — editing-oversight / PI
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-12-M5 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-12 · M5 — the NEC doesn't protect equipment
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-12-M7 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-12 · M7 — the hooks that exist
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-13-M1 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-13 · M1 — 517.13 structure
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-13-M2 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-13 · M2 — same-route redundant EGC
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-14-M1 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-14 · M1 — #8 ring geometry
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-14-M5 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-14 · M5 — A pump switch's bell box takes its EGC connection; it does not need a connection to the equipotential bonding grid
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-16-M5 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-16 · M5 — Recognized ≠ stand-alone
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-17-M2 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-17 · M2 — touch-it-you-own-it split, CONTESTED
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-17-M3 · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-17 · M3 — the contract shield
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-3-M6-Limb-A · Backed by a few shops · 4 points of shop evidenceContestedSafety-held
ED-3 · M6 Limb A — 220.83 reading, CONTESTED; its refusal limb is the same voice
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-4-M2 · Backed by a few shops · 4 points of shop evidenceContested
ED-4 · M2 — the derate/EMS relief valves, Shop 4 / Doc 0 — 625.42(A) wording editorially confirmed; relay upgraded, lane unmoved
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-14-M3-Side-A · Backed by a few shops · 4 points of shop evidenceContested
ED-14 · M3 Side A — 4/4, CONTESTED — the (B)(1)/(B)(2)/(B)(3) text verified; Side A's premise narrower than its conclusion, Side B's conclusion textually stronger; the residual seam an AHJ characterization; scores unchanged, contest persists
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-14-Side-B · Backed by a few shops · 4 points of shop evidenceContested
ED-14 · Side B — 4/4, CONTESTED — the (B)(1)/(B)(2)/(B)(3) text verified; Side A's premise narrower than its conclusion, Side B's conclusion textually stronger; the residual seam an AHJ characterization; scores unchanged, contest persists
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-20-M3 · Backed by a few shops · 4 points of shop evidenceContestedSafety-flagged
ED-20 · M3 — the cheap path; ◆3/◆4 shelf-life notes as M1's; ◆6 completable at 8 of 8 as M1's
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-20-M4 · Backed by a few shops · 4 points of shop evidenceContestedSafety-flagged
ED-20 · M4 — regional variance — the variance itself is the proposition; ◆3/◆4 shelf-life notes as M1's; ◆6 as M3's
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-21-M3-Limb-A · Backed by a few shops · 4 points of shop evidenceContestedSafety-flagged
ED-21 · M3 Limb A — the intermittency mechanism doctrine
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line); limb of member M3 — the court's 141-member count treats this member's limbs as one member (see READINESS.md)
ED-21-M4 · Backed by a few shops · 4 points of shop evidenceContestedSafety-flagged
ED-21 · M4 — reflected-wave damage hides from the megger
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-22-M1 · Backed by a few shops · 4 points of shop evidenceContestedSafety-flagged
ED-22 · M1 — the three-breaker gap, safety-flagged
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-22-M2 · Backed by a few shops · 4 points of shop evidenceContestedSafety-flagged
ED-22 · M2 — line-side topology, conservative attribution disclosed
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-22-M4 · Backed by a few shops · 4 points of shop evidenceContestedSafety-flagged
ED-22 · M4 — PG&E's tap crackdown
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-17-M7-Limb-B · Backed by a few shops · 4 points of shop evidenceContestedSafety-flagged
ED-17 · M7 Limb B — the integrity counter-position, CONTESTED limb
Shop 4 · Doc 0 · Total 4. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line); limb of member M7 — the court's 141-member count treats this member's limbs as one member (see READINESS.md)
ED-1-Limb-C · Backed by a few shops · 3 points of shop evidenceContestedSafety-flagged
ED-1 · Limb C — SAFETY: pressing a plug-in tester on an ungrounded receptacle can energize a metal cover plate toward line voltage
Shop 3 · Doc 0 · Total 3. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-6-M2 · Backed by a few shops · 3 points of shop evidenceContestedSafety-flagged
ED-6 · M2 — 250.64(C)(2)'s "sections of busbars connected together" means bolted busbar assemblies (analogous to the (C)(3) structural-steel case), not wires torqued into lugs
Shop 3 · Doc 0 · Total 3. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-6-M3 · Backed by a few shops · 3 points of shop evidenceContestedSafety-flagged
ED-6 · M3 — the 250.64(C) continuity pair, 3/3, CONTESTED
Shop 3 · Doc 0 · Total 3. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-6-M4 · Backed by a few shops · 3 points of shop evidenceContestedSafety-flagged
ED-6 · M4 — the 250.64(C) continuity pair, 3/3, CONTESTED
Shop 3 · Doc 0 · Total 3. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-9-M5s-correction · Backed by a few shops · 3 points of shop evidenceContestedSafety-flagged
ED-9 · M5's correction — ED-9 · M5's correction — register entry; see convergence-pass-7-increment.md §4 (register unchanged) and convergence-pass-1.md §4
Shop 3 · Doc 0 · Total 3. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
✕ Shown wrong
REFUTED — the Div 2 “2-inch rule” (thread 25474 post #5). Shop 2, points kept. Refuted in-thread by ED-9 M5's correction: the 2-inch rule is a Division 1 sealing rule (501.15(A)(2)), not a Division 2 box rule — the rule's own location refutes it, and the corrected poster accepted the correction in-thread. Capped below the correction.
ED-10-M3 · Backed by a few shops · 3 points of shop evidenceContestedSafety-flagged
ED-10 · M3 — the worked failing case
Shop 3 · Doc 0 · Total 3. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-14-M4b · Backed by a few shops · 3 points of shop evidenceContestedSafety-flagged
ED-14 · M4b — DB lugs need no change
Shop 3 · Doc 0 · Total 3. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-11-M4-Limb-A · Backed by a few shops · 3 points of shop evidenceContested
ED-11 · M4 Limb A — (statement in convergence-pass-7-increment.md §2 (compact docket line))
Shop 3 · Doc 0 · Total 3. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-18-M2-Limb-B · Backed by a few shops · 3 points of shop evidenceContested
ED-18 · M2 Limb B — the 210.12(E) text controls line-side extensions; ◆3 note: NC's in-force cycles leave that text exactly at base
Shop 3 · Doc 0 · Total 3. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
✕ Shown wrong
REFUTED — the 210.12(E) line-side reading (thread 2583767 post #5). Shop 2, points kept. Refuted in-thread by ED-18 M2 Limb B on the section's own text (the exception measures extension of the branch-circuit conductors, supply side included), and the refutation was accepted by its own proponent on rereading (post #7). Capped below Limb B (Shop 3). What survives, at its true weight: the poster's report that an AHJ permitted the practice in his case — a reported local practice, a fact about one AHJ's counter, not a reading of the section.
ED-22-M5 · Backed by a few shops · 3 points of shop evidenceContested
ED-22 · M5 — utility variance; grey-area limb self-flagged
Shop 3 · Doc 0 · Total 3. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-4-M10-Limb-B · Backed by a few shops · 3 points of shop evidenceContested
ED-4 · M10 Limb B — the 6-series limb, CONTESTED
Shop 3 · Doc 0 · Total 3. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-21-M3-Limb-B2 · Backed by a few shops · 3 points of shop evidenceContestedExport item_id collides with Limb B− in the court's export fileported under a suffixed id so both contested limbs stand — flagged for the court's export fix
ED-21 · M3 Limb B+ — raise the GF trip setting, CONTESTED limb
Shop 3 · Doc 0 · Total 3. Band: Building (3–5).
Provenance: convergence-pass-7-increment.md §2 (compact docket line); limb of member M3 — the court's 141-member count treats this member's limbs as one member (see READINESS.md)
ED-1-WI-3 · Early evidence · 2 points of shop evidenceContested
ED-1 · WI-3 refinement — Diagnostic refinement: read the AFCI's trip indicator; a tester resistance ≲4 kΩ may be tripping the AFCI's GFPE element, not its arc element
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-2-Limb-B · Early evidence · 2 points of shop evidenceContested
ED-2 · Limb B — single unattributed post
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-3-M1 · Early evidence · 2 points of shop evidenceContested
ED-3 · M1 — 220.84 method discipline: eligibility under (A) first; sum the (C) loads, then apply the Table factor; house loads under (B) get no factor
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-3-M2 · Early evidence · 2 points of shop evidenceContested
ED-3 · M2 — Never stack Part III demand tables (220.54/220.55) onto a Part IV optional calculation
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-3-M7 · Early evidence · 2 points of shop evidenceContested
ED-3 · M7 — When a 220.83 calculation runs close, verify real nameplate data in the field
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-3-M8 · Early evidence · 2 points of shop evidenceContested
ED-3 · M8 — 2026 restructure reportage, 2 — editorially corroborated, Doc 0, verification-not-anchor
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-3-M9 · Early evidence · 2 points of shop evidenceContested
ED-3 · M9 — EVSE-at-zero, 2
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-3-M13 · Early evidence · 2 points of shop evidenceContested
ED-3 · M13 — non-anchor by nature
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-4-M4 · Early evidence · 2 points of shop evidenceContested
ED-4 · M4 — CCID20 distinction, 2 — one-voice counting fact, flagged load-bearing
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-4-M6-Limb-A · Early evidence · 2 points of shop evidenceContested
ED-4 · M6 Limb A — CONTESTED
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-5-M2 · Early evidence · 2 points of shop evidenceContested
ED-5 · M2 — With a SunSpec or SolarEdge string inverter, the PV AC disconnect (or main service disconnect) is the initiator for all the PV
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-5-M3 · Early evidence · 2 points of shop evidenceContested
ED-5 · M3 — 690.56(C)(1) signage anticipates the mixed reality: multiple systems with different — or grandfathered, no — rapid shutdown, labeled as such
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-5-M4 · Early evidence · 2 points of shop evidenceContested
ED-5 · M4 — SunSpec on the spec sheet does nothing without module-level RS devices on the modules; the "keep alive" signal is a protocol, not a shutdown
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-6-M5 · Early evidence · 2 points of shop evidenceContested
ED-6 · M5 — The GEC may land at the meter can or another utility-side point; check the other electrodes before moving anything
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-6-M8 · Early evidence · 2 points of shop evidenceContested
ED-6 · M8 — Joining three circuits' neutrals onto one terminal creates an MWBC — handle ties, grouping, identification — unless a Polaris-type block gives each conductor its own termination, creating none
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-7-M2 · Early evidence · 2 points of shop evidenceContested
ED-7 · M2 — The rationale, as field experience: numbers stuck on breakers rot — breakers move, numbers scatter, half go missing, and the schedule becomes ambiguous between "41st slot" and "the breaker marked 41."
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-7-M4 · Early evidence · 2 points of shop evidenceContested
ED-7 · M4 — Tandem/piggyback breakers take letter-suffixed space numbers (1a, 1b, 3a, 3b)
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-8-M3 · Early evidence · 2 points of shop evidenceContested
ED-8 · M3 — Non-emergency transfer switches need not be identified for emergency use; only the emergency ATS carries that requirement
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-8-M5-Limb-B · Early evidence · 2 points of shop evidenceContested
ED-8 · M5 Limb B — 2; Limb A is a question at 0
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-9-M1 · Early evidence · 2 points of shop evidenceContested
ED-9 · M1 — There is no true "MC Ethernet cable" for Class I Div 2: MC must be 18 AWG or larger (330.1), so 22/24 AWG Ethernet cannot be type MC; armored-looking cable labeled CM is not a Div 2 method unless in RMC
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-9-M2 · Early evidence · 2 points of shop evidenceContested
ED-9 · M2 — ITC-ER under Article 727 is a workable Div 2 Ethernet method; some PLTC-ER is dual-rated; neither 500.15(B)(1)(4) nor 727.4 requires raceway
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-9-M7 · Early evidence · 2 points of shop evidenceContested
ED-9 · M7 — Caveat: no splices or wire nuts in short-radius conduit bodies (314.5), independent of the hazardous-location question
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-10-M2 · Early evidence · 2 points of shop evidenceContested
ED-10 · M2 — A load-side panel main breaker CAN serve as secondary conductor protection if 240.21(C) is met; same-room/within-sight proximity does not remove the requirement
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-10-M4 · Early evidence · 2 points of shop evidenceContested
ED-10 · M4 — The cure that keeps the no-secondary-OCPD design: shrink the primary device (15 A breaker → 5 A fuses) to satisfy both tests at once; or add the 30 A secondary breaker and satisfy both the other way
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-11-M1 · Early evidence · 2 points of shop evidenceContested
ED-11 · M1 — The FACP's 120 V input power is not a fire alarm circuit; PLFA/NPLFA classification applies to circuits fed from the panel
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-11-M3 · Early evidence · 2 points of shop evidenceContested
ED-11 · M3 — NPLFA is not extinct: legacy (Pyrotronics F3/5A ionization circuit, ~240 V) and modern (Siemens ZAM-180 voice-amplifier output) examples
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-11-M4-Limb-B · Early evidence · 2 points of shop evidenceContested
ED-11 · M4 Limb B — (statement in convergence-pass-7-increment.md §2 (compact docket line))
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-11-M5 · Early evidence · 2 points of shop evidenceContested
ED-11 · M5 — Before reclassifying any power-limited circuit, verify no device on it requires a power-limited input — the often-overlooked failure point (shared with Class 2/3 reclassification)
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-12-M3 · Early evidence · 2 points of shop evidenceContested
ED-12 · M3 — 2026 permissive dissent, 2
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-12-M6 · Early evidence · 2 points of shop evidenceContested
ED-12 · M6 — The accepted design model is single-point grounding (Motorola R56 pattern): all audio-line SPDs bonded to a common bar, the bar bonded to the building GES — the cell-tower approach
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-13-M4 · Early evidence · 2 points of shop evidenceContested
ED-13 · M4 — Consequently, redundancy alone is insufficient: a wiring method whose outer enclosure cannot serve as a qualified EGC return path sits outside 517.13's intent, however many copper conductors it carries
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-15-M2 · Early evidence · 2 points of shop evidenceContested
ED-15 · M2 — leakage rationale, 2
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-16-M3a · Early evidence · 2 points of shop evidenceContested
ED-16 · M3a — fault magnitudes, 2
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-16-M6 · Early evidence · 2 points of shop evidenceContested
ED-16 · M6 — default 5 kA, 2, open
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-13-M3 · Early evidence · 2 points of shop evidence
ED-13 · M3 — the 517.13 author's history, 2 — mechanism corroborated at relay weight by NFPA 99's annex; figures and meeting narrative still single-author; score unchanged
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-18-M1 · Early evidence · 2 points of shop evidenceContested
ED-18 · M1 — the 210.12(E) base case, 2, edition incomplete
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-21-M6 · Early evidence · 2 points of shop evidenceContested
ED-21 · M6 — the pre-charge/transient mechanism, 2, single-post capture, author's own guess label carried
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-21-M7 · Early evidence · 2 points of shop evidenceContested
ED-21 · M7 — 430.122 at 125% of drive input, 2, edition incomplete
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-21-M3-Limb-B · Early evidence · 2 points of shop evidenceContestedExport item_id collides with Limb B− in the court's export fileported under a suffixed id so both contested limbs stand — flagged for the court's export fix
ED-21 · M3 Limb B− — never raise the setting, 2, CONTESTED limb
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line); limb of member M3 — the court's 141-member count treats this member's limbs as one member (see READINESS.md)
ED-22-M3 · Early evidence · 2 points of shop evidenceContested
ED-22 · M3 — the ATS misconception correction, 2
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-4-M10-Limb-A · Early evidence · 2 points of shop evidenceContested
ED-4 · M10 Limb A — never float a 14-series neutral, 2, CONTESTED limb
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-17-M4 · Early evidence · 2 points of shop evidenceContested
ED-17 · M4 — the others'-work contract clause, 2
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-17-M6 · Early evidence · 2 points of shop evidenceContested
ED-17 · M6 — the exposure premise, 2, jurisdiction-varies
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-17-M8 · Early evidence · 2 points of shop evidenceContested
ED-17 · M8 — the inspector's own account, 2 — bottom by arithmetic, flagged as M1's other-side confirmation
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-23-M1 · Early evidence · 2 points of shop evidence
ED-23 · M1 — 700.17(2)'s two-branch-circuit / separate-systems rule, 2 — Handbook explanation flagged explanatory material, not code text; edition incomplete; the OP's hedged exit-door extension preserved as his reading only
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-23-M2 · Early evidence · 2 points of shop evidence
ED-23 · M2 — the split-ATS design consequence, 2 — stated design intent, not an installed outcome
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-8-M7 · Early evidence · 2 points of shop evidence
ED-8 · M7 — the 700.5(D) corollary: non-emergency lights belong on Standby Power, 2 — ED-8 M1's doctrine in application
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-17-M9 · Early evidence · 2 points of shop evidenceSingle voice
ED-17 · M9** — contract scope language: state the scope, state that out-of-scope work may become necessary — petersonra; companion to M3, not merged; Increment 5 §1
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (★5 barrel line); scores per convergence-pass-6-increment.md
ED-17-M11 · Early evidence · 2 points of shop evidenceSingle voice
ED-17 · M11** — the added load is yours: the skipped load calculation for your own added load is your own violation — hornetd; ED-17's scope boundary, cross-referenced to ED-3, not seated there; Increment 5 §1
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (★5 barrel line); scores per convergence-pass-6-increment.md
ED-17-M13 · Early evidence · 2 points of shop evidenceSingle voice
ED-17 · M13 — nonconformance timelines: 90-day / 1-year correction tracks, egregious end at 10 business days under license/CO threat — Elect117; jurisdiction unnamed in the post, carried as that poster's practice; ◆6 hunted — hunt-24: the two-track regime was not locatable in published official rules; the published windows found are short and single-track (Fort Worth 10 days; OR OAR 918-271-0030, 20 days), banked as context only; not a refutation**, score unchanged; §1 ◆6-5, §6
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (★5 barrel line); scores per convergence-pass-6-increment.md
ED-17-M15 · Early evidence · 2 points of shop evidenceSingle voice
ED-17 · M15 — Maryland CO doctrine, stated as local and carried only as Maryland-scoped: pulling any permit on an existing building under renovation suspends its CO — WD40; single-voice legal characterization; ◆6 hunted — hunt-23 read COMAR 09.12.51.04 firsthand: no state-level anchor exists; CO issuance and Chapter 1 amendments are expressly local-jurisdiction matters in Maryland, so the claim carries a documented scope problem flagged for the court; the claim names no county, so no local rule could be located or excluded; not a refutation**, score unchanged; §1 ◆6-5, §6
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (★5 barrel line); scores per convergence-pass-6-increment.md
ED-17-M16 · Early evidence · 2 points of shop evidenceSingle voice
ED-17 · M16** — the danger-scale mention threshold: not yours to fix, but some pre-existing violations are too dangerous to leave unraised — CoolWill; the working side's companion to M12; Increment 5 §1
Shop 2 · Doc 0 · Total 2. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (★5 barrel line); scores per convergence-pass-6-increment.md
ED-4-M3 · Early evidence · 1 points of shop evidenceContested
ED-4 · M3 — Gen2 product fact, 1
Shop 1 · Doc 0 · Total 1. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-9-M3 · Early evidence · 1 points of shop evidenceContested
ED-9 · M3 — opinion specimen
Shop 1 · Doc 0 · Total 1. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
ED-14-M4a · Early evidence · 1 points of shop evidenceContested
ED-14 · M4a — Hubbell relay, 1
Shop 1 · Doc 0 · Total 1. Band: Bottom barrel (0–2).
Provenance: convergence-pass-7-increment.md §2 (compact docket line)
Reference only. Compiled from the cited official sources as of the date shown; adoptions and rules change. Confirm with the authority having jurisdiction before designing or permitting work.